At Advanced Air Quality, we don’t just promise quality, we deliver. We offer the most cost-effective way to clean your coils and improve your indoor air quality.

WHAT CAN YOU EXPECT IF YOUR COILS AREN’T KEPT CLEAN?
- Higher energy costs
- Unnecessary repair bills
- Lack of humidity removal
- Component or compressor failures
- Loss of heating or cooling capacity
- Mold and bacteria growth
CALL US TO GET A FREE ESTIMATE
OR VISIT OUR CONTACT PAGE
FACTS
- Annual cleaning of HVAC coils can reduce energy consumption significantly — often enough to pay for the cleaning cost within six months.
- For every dollar spent on proper coil cleaning, there is an equal dollar saved in energy costs per unit.
- Neglecting condenser and evaporator coils can increase energy consumption by at least 15% per unit.
- Coil cleaning saves money by extending the operating life of each unit and reducing runtime.
| Unit Size | Volts | Amps | Watts | kW | Annual Cost | Increase in Energy Use (Dirty Coils) | 10¢ / kWh | 15¢ / kWh | 20¢ / kWh |
|---|---|---|---|---|---|---|---|---|---|
| 5 Ton Unit | 480 | 20 | 16608 | 16.6 | $1792.00 | 0% with clean coils | - | - | - |
| 480 | 21 | 17483 | 17.4 | $1879.00 | 5% | $87.00 | $130.50 | $174.00 | |
| 480 | 22 | 18268 | 18.2 | $1965.00 | 10% | $173.00 | $259.00 | $346.00 | |
| 480 | 23 | 19099 | 19.1 | $2062.00 | 15% | $270.00 | $405.00 | $540.00 | |
| 10 Ton Unit | 480 | 40 | 33216 | 32.2 | $3584.00 | 0% with clean coils | - | - | - |
| 480 | 42 | 34966 | 34.8 | $3758.00 | 5% | $174.00 | $261.00 | $348.00 | |
| 480 | 44 | 36536 | 36.4 | $3930.00 | 10% | $346.00 | $519.00 | $692.00 | |
| 480 | 46 | 38198 | 38.2 | $4124.00 | 15% | $540.00 | $810.00 | $1080.00 | |
| 20 Ton Unit | 480 | 80 | 66432 | 66.4 | $7168.00 | 0% with clean coils | - | - | - |
| 480 | 84 | 69753 | 69.6 | $7516.00 | 5% | $348.00 | $522.00 | $696.00 | |
| 480 | 88 | 73072 | 72.8 | $7860.00 | 10% | $692.00 | $1038.00 | $1384.00 | |
| 480 | 92 | 76396 | 76.4 | $8248.00 | 15% | $1080.00 | $1620.00 | $2160.00 |

WHY CHOOSE ADVANCED AIR QUALITY?
-
CERTIFIED AIR DUCT CLEANING TECHNICIANS
-
ADVANCED CLEANING TECHNOLOGY
-
DRYER VENT CLEANING SPECIALISTS
-
COMPLETE CLEANING & INSPECTIONS
-
AWARD-WINNING LOCAL SERVICE
-
NADCA CERTIFIED

ANNUAL CLEANING
OF HVAC COILS
Annual HVAC coil cleaning can reduce energy consumption significantly — often enough to cover the cleaning cost within six months.

EQUAL DOLLAR IN
ENERGY SAVINGS
For every dollar spent on proper coil cleaning, you can expect an equal dollar in energy savings for each unit.


NEGLECTING COILS CAN INCREASE
ENERGY CONSUMPTION
Neglecting condenser and evaporator coils can increase a unit’s energy consumption by at least 15%.

COIL CLEANING
SAVES MONEY
Coil cleaning saves money by extending the operating life of each unit and reducing runtime.

HVAC COIL CLEANING PROCESS
-
STEP 1 POWER IS DISCONNECTEDPower is disconnected from the unit, and coils are vacuumed with our HEPA vacuums.
-
STEP 2 BEFORE PICTURES TAKENHigh-quality “before” pictures are taken of the coils and unit.
-
STEP 3 ENCLOSURE IS SET UPAn enclosure is set up and placed under negative pressure with a HEPA air scrubber.
-
STEP 4 COILS CLEANED ON BOTH SIDESCoils are cleaned on both sides with our high-pressure steamer, using only water. This process removes stuck-on debris and disinfects with 230-degree Celsius dry vapour steam.
-
STEP 5 COIL COMB USEDWe use a coil comb to straighten damaged fins, instantly improving coil performance and restoring it to near-new condition.
-
STEP 6 COILS SPRAYEDCoils are sprayed with either our all-natural disinfectant Benefect or with Cal-Green, an environmentally friendly coil cleaning solution.
-
STEP 7 AFTER PICTURES TAKENHigh-quality “after” pictures are taken and any deficiencies are noted.
-
STEP 8 POWER IS RESTOREDPower is restored to the unit.
HVAC COIL CLEANING PROCESS
-
STEP 1 HIGH-QUALITY "BEFORE" PICTURESHigh-quality "before" pictures are taken of the coils and unit.
-
STEP 2 POWER IS DISCONNECTEDPower is disconnected from the unit, and coils are vacuumed with our HEPA vacuums.
-
STEP 3 ENCLOSURE IS SET UPAn enclosure is set up and placed under negative pressure with a HEPA air scrubber.
-
STEP 4 COILS ARE CLEANED ON BOTH SIDESCoils are cleaned on both sides with our high-pressure steamer, using only water. This process removes stuck-on debris and disinfects with 230-degree dry vapour steam.
-
STEP 5 STRAIGHTEN DAMAGED FINSUsing a coil comb, we straighten damaged fins. This instantly improves coil performance and restores it to near-new condition.
-
STEP 6 COILS ARE SPRAYEDCoils are sprayed with either our all-natural disinfectant Benefect or Cal-Green, an environmentally friendly coil cleaning solution.
-
STEP 7 HIGH-QUALITY "AFTER" PICTURESHigh-quality "after" pictures are taken and any deficiencies are noted.
-
STEP 8 POWER IS RESTOREDPower is restored to the unit.
WE’LL REVIEW OUR WORK WITH YOU BEFORE AND AFTER THE CLEANING, AND WE DON’T CONSIDER THE JOB DONE UNTIL YOU’RE COMPLETELY SATISFIED.
DISCOVER WHY WE’RE THE #1 CHOICE IN OTTAWA FOR AIR DUCT CLEANING SERVICES.
TO GET A FREE ESTIMATE 
CALL US TODAY
OR VISIT OUR CONTACT PAGE